Passer aux informations produits
1 de 1

TEXONIC

TEXONIC PA260 260W 2-Zone Commercial Mixer Amplifier with Bluetooth & Paging

TEXONIC PA260 260W 2-Zone Commercial Mixer Amplifier with Bluetooth & Paging

SKU:PA260

Prix habituel $699.98 CAD
Prix habituel Prix promotionnel $699.98 CAD
Promotion Épuisé
Frais d'expédition calculés à l'étape de paiement.
Quantité
260W COMMERCIAL AUDIO | TWO-ZONE MUSIC & PAGING

TEXONIC PA260 2-Zone Commercial Mixer Amplifier

The TEXONIC PA260 is a 260W commercial mixer amplifier that brings music playback, microphone announcements and two-area speaker control into one central audio unit.

Designed for 100V distributed speaker installations, the PA260 provides two selectable speaker zones so businesses can direct background music and paging to the areas where sound is needed.

Built-in Bluetooth, FM radio, USB and SD playback offer convenient music sources. Four microphone channels, two auxiliary inputs and MIC1 voice-priority paging provide flexibility for daily communication and audio playback.

With a separate 4–16Ω output option, tone adjustment, microphone echo control and line-level outputs, the PA260 can be integrated into a variety of properly designed commercial speaker systems.

260W Rated Output 2 Selectable Zones 100V Commercial Audio Bluetooth / FM / USB / SD MIC1 Priority Paging
Manual

Flexible Background Audio for Two Connected Areas

The PA260 provides one central location for managing music and routine announcements in two separate speaker areas. Instead of requiring two independent amplifiers, compatible 100V speakers can be organized into two circuits.

Front-panel zone switches allow staff to enable Zone 1, Zone 2 or both areas together. The amplifier's music and microphone programme is shared between active zones.

This approach is useful for facilities where different parts of a building may not require sound at the same time, but can share one audio source.

Where the PA260 Fits

Office & Administration Provide background sound in reception and shared workspaces, with paging available through a compatible microphone.
Retail & Customer Service Organize speakers between customer-facing areas and staff or support spaces.
Community & Training Rooms Use music or announcements in two selectable rooms sharing a central audio system.
Hospitality & Recreation Distribute background music through common areas while keeping secondary speaker circuits selectable.
Important Zone Distinction: Zone 1 and Zone 2 share the same music and paging programme. The front-panel zone switches provide area selection, not independent music-source routing or separate built-in zone volume controls.

Choose Between Built-In and External Audio

The PA260 includes Bluetooth and FM radio playback, as well as USB and SD media connections.

Two rear AUX inputs are also available for compatible external equipment such as a media streamer, computer audio source or music player.

The amplifier can mix compatible microphone and auxiliary signals, allowing background music and routine voice communication to be handled from one unit.

Microphone Paging and Announcements

Four microphone channels provide connection options for speech, announcements and other suitable microphone applications.

MIC1 and MIC2 have convenient front-panel ¼-inch connections. MIC3 and MIC4 use rear-panel combo microphone connections.

The MIC1 priority switch can reduce background music during voice announcements, helping the spoken message stand out from the regular audio programme.

Line-Level Expansion

REC and LINE outputs are provided for connection to compatible external audio equipment.

The line output can feed a suitable external power amplifier or active subwoofer when additional audio equipment is required.

System Expansion Tip: The LINE connection is a line-level audio signal, not an additional powered speaker output.

Compatible Commercial Speakers

The PA260 can be used with appropriately configured commercial ceiling speakers and other compatible 100V transformer speakers.

For more information on distributed and low impedance speaker systems, read the  TEXONIC 70V vs. 8-Ohm Speaker Guide .

Key Features

  • 260W rated commercial mixer amplifier
  • Two selectable 100V speaker zones
  • Front-panel Zone 1 and Zone 2 switches
  • Direct 100V speaker output option
  • Separate 4–16Ω low-impedance output
  • Built-in Bluetooth audio playback
  • Integrated FM radio receiver
  • USB and SD media playback
  • MP3 and WMA audio format support
  • Four microphone input channels
  • Front-panel MIC1 and MIC2 ¼-inch inputs
  • Rear MIC3 and MIC4 combo inputs
  • 48V phantom power switch for compatible microphones
  • MIC1 voice-priority ducking function
  • Two external AUX audio inputs
  • Individual MIC1–MIC4 level adjustments
  • Separate AUX1 and AUX2 volume controls
  • Built-in chime function
  • Built-in siren function
  • Adjustable microphone echo control
  • Bass and treble tone adjustments
  • Master output volume control
  • LED audio level meter
  • Front-panel LCD media display
  • Rear REC audio output
  • Line output for compatible external equipment
  • AC 120V, 60Hz operation
Microphone Compatibility: The rear-panel MIC3 and MIC4 connections support suitable microphones requiring phantom power. Confirm the microphone's requirements before enabling the 48V switch.

Priority Paging

The rear-panel MIC1 priority switch enables or disables voice-priority ducking.

When enabled, announcements through MIC1 can lower the background music level. This is useful for regular business paging where voice communication must temporarily take precedence.

Chime and Siren Controls

Dedicated front-panel buttons provide access to the amplifier's built-in chime and siren functions.

These functions can be used where appropriate for general-purpose commercial audio announcements.

Safety Notice: The presence of a siren function does not establish certification as a regulated fire-alarm or emergency voice-evacuation system.

Microphone Echo Adjustment

The front-panel MIC ECHO control allows adjustment of the microphone echo effect for suitable voice applications.

For straightforward speech paging, use an appropriate setting that preserves announcement clarity.

Individual Source Levels

Separate microphone, auxiliary and media-player level controls allow compatible connected sources to be balanced before the final master volume is adjusted.

Technical Specifications

Brand TEXONIC
Model / SKU PA260
Product Type 2-Zone Commercial Mixer Amplifier
Rated Output Power 260W total
Power Rating Condition 1kHz, THD+N = 1%
Number of Zones 2 selectable zones
Commercial Zone Outputs 100V Zone 1 / Zone 2
Additional Speaker Output Direct 100V
Low-Impedance Output 4–16Ω
Built-In Music Sources Bluetooth / FM / USB / SD
Supported Audio Formats MP3 / WMA
Microphone Channels 4
MIC1 / MIC2 Connections Front-panel ¼-inch (6.35mm)
MIC3 / MIC4 Connections Rear-panel XLR / ¼-inch combo
Phantom Power 48V switch for supported MIC inputs
MIC1 Priority Selectable ON / OFF ducking
AUX Inputs AUX1 / AUX2
Audio Outputs REC / LINE
Additional Sound Functions Chime / Siren / Microphone Echo
Tone Controls Bass / Treble
Level Controls Microphone / AUX / Media / Master
Output Monitoring Front-panel LED level meter
Frequency Response 100Hz–15kHz (±3dB, 8Ω, 1W)
THD+N ≤1% at 1kHz, half power
Signal-to-Noise Ratio ≥50dB
Line Input Sensitivity ≤350mV
MIC Input Sensitivity ≤15mV
Power Requirement AC 120V, 60Hz
Dimensions (Inches) 16.93 × 3.46 × 12.99in
Net Weight 10.5kg / 23.15lb
Output Compatibility: Select a speaker output configuration that matches the connected speakers. Do not use the two-zone speaker configuration and low-impedance speaker configuration simultaneously.

Understanding the Two Speaker Zones

The PA260 provides separate front-panel switches for Zone 1 and Zone 2.

Each zone represents a connected speaker circuit that can be enabled or disabled depending on the areas requiring music or announcements.

Zone 1 — Main Area For example, the primary customer area, lobby, main workspace or larger common room.
Zone 2 — Secondary Area For example, a staff room, reception, adjacent room or secondary commercial space.

Available Zone Selection

Zone 1 Only Send the amplifier's shared programme to Zone 1.
Zone 2 Only Send the amplifier's shared programme to Zone 2.
Both Zones Enable both areas to receive the same programme audio.
Combined Amplifier Power Both zones share the amplifier's 260W rated capacity.
Important: The PA260 does not provide separate music sources for each zone. It also does not have independent built-in volume controls for Zone 1 and Zone 2.
Need Room-by-Room Volume Adjustment? Compatible 100V wall volume controls may be considered for suitable installations. Check the volume control power rating and the total speaker tap loading.

Choosing Between Speaker Outputs

Two 100V Zones Use for two selectable commercial speaker areas.
Direct 100V Output Provides another documented 100V terminal option. Follow the manual's output wiring instructions.
4–16Ω Output For compatible low-impedance speaker arrangements.
Correct Configuration Check amplifier terminals, speaker transformer settings and wiring before powering on.
Speaker Connection Warning: Do not connect the two-zone speaker system and low-impedance speaker system at the same time. Turn off the amplifier before connecting or changing speaker wiring.

260W Speaker Loading & System Planning

For 100V distributed audio, the speaker load is calculated by adding the selected transformer wattage taps of all connected speakers.

The PA260 provides 260W of rated amplifier power shared across its speaker system.

As a conservative system planning approach, allowing 20% amplifier headroom gives a suggested total connected 100V speaker tap load of approximately 208W.

260W Rated amplifier output
208W Conservative planning load
52W 20% planning headroom
Planning Guideline: The 208W value is calculated using a conservative 20% power reserve. It is an installation design recommendation, not a separate manufacturer power rating.

Example Two-Zone Speaker Installation

Consider a business with two 100V speaker areas using commercial ceiling speakers set to 10W each.

Area Speakers 100V Tap Zone Load
Zone 1 — Main Area 10 10W 100W
Zone 2 — Secondary Area 8 10W 80W
Combined System 18 10W 180W

This example produces a combined 180W speaker load, leaving 80W of unused rated amplifier capacity.

Both zones can receive the same background music and paging programme when selected.

More 100V Speaker Loading Examples

Speakers Tap Each Total Load Capacity Remaining
6 6W 36W 224W
12 10W 120W 140W
16 10W 160W 100W
20 10W 200W 60W
Speaker Selection: These examples apply only to compatible 100V speakers offering the stated transformer tap settings. Final speaker quantity and placement depend on coverage requirements, mounting height and background noise.

Can I Connect Regular 8Ω Speakers?

Yes. The PA260 provides a separate 4–16Ω low-impedance output for suitable speaker configurations.

The total connected speaker impedance must remain within the amplifier's supported range. Do not use 100V transformer tap calculations for low-impedance speaker systems.

Can I Connect Another Amplifier?

Yes. The line output can feed compatible external audio equipment, including an additional commercial power amplifier or active subwoofer.

The connected equipment must accept the appropriate line-level signal.

Installation & Initial Setup

Before operating the PA260, verify the speaker system, audio input connections and selected output mode.

Before Turning On the Amplifier

  • Disconnect AC power before working on speaker terminals.
  • Confirm that 100V speakers are connected to the appropriate commercial speaker outputs.
  • Check the transformer wattage tap settings of every connected speaker.
  • Calculate the total speaker load across both zones.
  • Check wiring polarity and inspect for short circuits.
  • Verify the intended microphone and AUX connections.
  • Enable phantom power only for suitable microphones.
  • Start with microphone, media, AUX and master volumes at low levels.
  • Keep the amplifier's ventilation areas clear.

Testing the Two Zones

Select a suitable audio source and activate Zone 1 only.

Gradually increase the source and master volume to confirm normal sound.

Repeat for Zone 2, then test both zones together at the intended operating level.

Testing Microphone Priority

Connect a compatible paging microphone to MIC1.

Enable the rear MIC1 priority switch, play background music and make a test announcement.

Confirm that the music level is reduced during the announcement.

Installation Reminder: Never connect incompatible speaker output configurations at the same time. Incorrect wiring or speaker loading can damage audio equipment.
Commercial Music Use: Businesses in Canada may need appropriate public-performance music licensing for background music or radio. Confirm the requirements applicable to the facility.

What's Included

1 × TEXONIC PA260 260W 2-Zone Commercial Mixer Amplifier
AC Power Cable
User Manual 

Before Installation: Review the speaker output terminals, microphone input options, phantom power switch and MIC1 priority setting.

Tout neuf

Tous nos produits Texonic sont neufs et nous ne vendons pas d'articles remis à neuf

garantie

L'un de nos principaux objectifs est de fournir à nos clients les meilleurs produits et services. Tous nos produits TEXONIC sont couverts par une garantie de fabrication de 3 ans.

Expédition

L'heure limite d'expédition est 13 h 00 est. Si vous passez une commande avant 13 h 00, nous expédierons votre commande le même jour ouvrable. Si vous passez la commande après l'heure limite, pas de soucis, votre commande sera expédiée le jour ouvrable suivant.

Afficher tous les détails

Besoin d'assistance?

Vous avez du mal à décider quel produit convient à votre projet ou vous avez des questions ? Ne vous inquiétez pas, nous sommes heureux de vous aider. Vous pouvez nous appeler , nous envoyer un texto ou nous envoyer un courriel ☺